CARES Technical Approvals

Copies of the Technical Approval Reports can be downloaded in Adobe PDF format by clicking on the cover of the report below.

(Please note that files are typically 1mb and can be up to 2mb in size and may take a few minutes to download.)


Cares Technical Approval Report TA2-5001

Halfen Kwikastrip is a reinforcement product designed to maintain continuity across construction joints in concrete structures, consisting of selected reinforcement, pre-bent and housed in a purpose-designed carrier casing manufactured from indented galvanised steel.

Further details are given in CARES Technical Approval Report TA2-5001.

HALFEN Ltd
Humphrys Road
Woodside Estate
Dunstable
England LU5 4TP
Tel: +44 1582 470300
Fax: +44 1582 470304
E-mail: info@halfen.co.uk
Web: www.halfen.co.uk



Cares Technical Approval Report TA1C-5003

ERICO Lenton Taper Threaded Couplers standard (A12) and positional (P13 & P14) mechanical couplers to reinforcing steel in accordance with:

CARES Quality and Operations Assessment Schedule TA1-C, including the performance requirements of BS 8110: Part 1and the BNFL Technical Standard A.0391 for type B Couplers for Seismic Category 1, 2, and 3 structures under static loading conditions in tension only.

Further details are given in CARES Technical Approval Report TA1-C 5003.

ERICO BV
Jules Verneweg 75
5015 BG, Tilburg
The Netherlands
Tel: +31 1358 35400
Fax: +31 1358 35499
Web: www.erico.com



Cares Technical Approval Report TA1B-5005

Dextra GRIPTEC Swaged, parallel threaded standard, positional and transitional mechanical couplers to reinforcing steel, complying with:

1. CARES Quality and Operations Assessment Schedule TA1-B for use in tension under static loading conditions in the size range 12-50mm in accordance with Technical Approval Report TA1B-5005

Further details are given in CARES Technical Approval Report TA1-B 5005.

DEXTRA Manufacturing Co. Ltd
5th Floor Lumpini II Building
247 Sarasin Road
Lumpini Pathumwan
Bangkok 10330
Thailand
Tel:  +66 2651 9027
Fax: +66 2651 8000



Cares Technical Approval Report TA1B-5006

Halfen HBM Mechanical Couplers:

1.CARES Quality and Operations Assessment Schedule TA1-B for use in tension under static loading conditions in the size range 12-32mm in accordance with Technical Approval Report TA1B-5006

Further details are given in CARES Technical Approval Report TA1-B 5006.

HALFEN Ltd
Humphrys Road
Woodside Estate
Dunstable
England LU5 4TP
Tel: +44 1582 470300
Fax: +44 1582 470304
E-mail: info@halfen.co.uk
Web: www.halfen.co.uk



Cares Technical Approval Report TA2 5007

RFA Startabox continuity system is designed to maintain continuity of reinforcing steel across construction joints in concrete structures, consisting of selected reinforcement, pre-bent and housed in carrier casing manufactured from perforated galvanised steel.

Further details are given in CARES Technical Approval Report TA2-5007.

RFA Group Ltd
710 Brightside Lane
Sheffield
South Yorkshire
S9 2BR
Tel: +44 1142 317900
Fax: +44 1142 317905



Cares Technical Approval Report TA1B-5008

ERICO Lenton P13-35 & P13-45 Taper Threaded Couplers to reinforcing steel in accordance with:

1.CARES Quality and Operations Assessment Schedule TA1-B, including the performance requirements of BS 8110: Part 1: 1997 use in tension or compression under static loading conditions in the size range 25-50mm.

Further details are given in CARES Technical Approval Report TA1-B 5008.

ERICO BV
Jules Verneweg 75
5015 BG, Tilburg
The Netherlands
Tel: +31 1358 35400
Fax: +31 1358 35499
Web: www.erico.com



Cares Technical Approval Report TA1B-5009

ERICO Lenton Plus A12 (Standard) and P13/14 (Positional) taper threaded mechanical couplers to reinforcing steel, complying with:

1. CARES Quality and Operations Assessment Schedule TA1-C, which includes the performance requirements of:

2. BS 8110 Part 1 and BNFL Technical Standard A.0391 for Type A mechanical splices for Seismic Category 4 structures under static loading conditions in tension only in the size range 16-40mm and in accordance with Technical Approval Report TA1C-5009 issue 2.

Further details are given in CARES Technical Approval Report TA1-C 5009.

ERICO BV
Jules Verneweg 75
5015 BG, Tilburg
The Netherlands
Tel: +31 1358 35400
Fax: +31 1358 35499
Web: www.erico.com



Cares Technical Approval Report TA1B-5010

ROMTECH pile cage formers for use in accordance with CARES Appendix TA5 and Technical Approval Report TA5-5010:

Further details are given in CARES Technical Approval Report TA5 5010.

ROMTECH
Unit 16 Watling Street Business Park
Watling Street
Norton Canes
Cannock
Staffordshire
WS11 9XG
Tel: +44 1543 364399
Fax: +44 1543 364321



Cares Technical Approval Report TA1B-5011

Dextra BARTEC parallel threaded standard mechanical couplers to reinforcing steel, complying with:

1. CARES Quality and Operations Assessment Schedule TA1-B for use in tension under static loading conditions in the size range 16mm-40mm in accordance with Technical Approval Report TA1B-5011.

Further details are given in CARES Technical Approval Report TA1-B 5011.

DEXTRA Manufacturing Co. Ltd,
5th Floor Lumpini II Building
247 Sarasin Road
Lumpini Pathumwan
Bangkok 10330
Thailand
Tel:  +66 2651 9027
Fax: +66 2651 8000



Cares Technical Approval Report TA1B-5012

ERICO Lenton Form Saver taper threaded mechanical couplers to reinforcing steel, complying with:

1. CARES Quality and Operations Assessment Schedule TA1-B, which includes the performance requirements of BS 8110 Part 1 under static loading conditions in tension only in the size range 32 and 40mm and in accordance with Technical Approval Report TA1-B-5012.

ERICO BV
Jules Verneweg 75
5015 BG, Tilburg
The Netherlands
Tel: +31 1358 35400
Fax: +31 1358 35499
Web: www.erico.com



Cares Technical Approval Report TA7-5013

Halfen HBD Punching Shear Stud System

1. HDB Punching Shear Stud System for use in reinforced concrete floors designed in accordance with BS8110:Part 1: 1997 (Revised 2005) for use with static loading comprising double headed studs in diameters from B10 to B25 and in lengths from 125 mm to 455 mm for use in accordance with Technical Approval Report TA7-5013.

HALFEN Ltd
Humphrys Road
Woodside Estate
Dunstable
England LU5 4TP
Tel: +44 1582 470300
Fax: +44 1582 470304
E-mail: info@halfen.co.uk
Web: www.halfen.co.uk



Cares Technical Approval Report TA7-5014

Dextra GRIPTEC Swaged, parallel threaded standard and positional mechanical couplers to reinforcing steel, complying with:

1. CARES Quality and Operations Assessment Schedule TA1-B for use in tension under static loading conditions: standard couplers in the size range 12-40mm and positional couplers in the size range 16-40mm in accordance with Technical Approval Report TA1C-5014.

2. CARES Quality and Operations Assessment Schedule TA1-C; Griptec standard and positional couplers for BNFL applications for type B and type A couplers as detailed in accordance with CARES Technical Approval Report TA1C-5014.

Further details are given in CARES Technical Approval Report TA1-C 5014.

DEXTRA Manufacturing Co. Ltd,
5th Floor Lumpini II Building
247 Sarasin Road
Lumpini Pathumwan
Bangkok 10330
Thailand
Tel:  +66 2651 9027
Fax: +66 2651 8000



Cares Technical Approval Report TA1B-5015

Ancon Taper Thread Reinforcing Bar Couplers

Taper Threaded Couplers, standard, positional and transitional mechanical couplers to reinforcing steel in accordance with CARES Quality and Operations Assessment Schedule TA1-B, including the performance requirements of BS 8110: Part 1 for use in tension only under static loading conditions in the size range 12-40mm.

Further details are given in CARES Technical Approval Report TA1-B 5015.

Ancon Building Products
President Way
President Park
Sheffield
South Yorkshire
S4 7UR
Tel: +44 114 275 5224
Fax: +44 114 238 1240
Web: www.ancon.co.uk



Cares Technical Approval Report TA1B-5016

Boo Won BMS parallel threaded mechanical couplers to reinforcing steel, complying with:

CARES Quality and Operations Assessment Schedule TA1-B for use in tension under static loading conditions in the size range 16mm-40mm in accordance with Technical Approval Report TA1B-5016.

Further details are given in CARES Technical Approval Report TA1-B 5016.

Boo Won BMS CO. Ltd
#590 Yongtan-Dong
Chungju-City
Chungbuk
Korea
Tel: +82 43 856 6640
Fax: +82 43 856 6643



Cares Technical Approval Report TA2-5017

Ancon Eazistrip is a reinforcement product designed to maintain continuity across construction joints in concrete structures, consisting of selected reinforcement, pre-bent and housed in a purpose-designed carrier casing manufactured from indented galvanised steel:

Further details are given in CARES Technical Approval Report TA2 5017.

Ancon Building Products
President Way
President Park
Sheffield
South Yorkshire
S4 7UR
Tel: +44 114 275 5224
Fax: +44 114 238 1240
Web: www.ancon.co.uk



Cares Technical Approval Report TA10-5018

North American Stainless Ribbed duplex (1.4362) stainless steel reinforcing bar 12mm - 25mm.

Further details are given in Techncial Approval Report TA10 5018.

North American Stainless (NAS)
6870 Highway 42 East
Ghent
Kentucky, 41045-9615
USA
Tel: +1 502-347-6000
Fax: +1 502-347-6001



Cares Technical Approval Report TA10-5019

Arminox Ribbed duplex (1.4362) stainless steel reinforcing bar 6mm - 12mm.

Further details are given in Techncial Approval Report TA10 5019.

Arminox
Jernvej 22
Monsted DK-8800
Viborg
DENMARK
Tel: + 45 86 64 50 11
Fax: + 45 86 64 57 11



Cares Technical Approval Report TA10-5020

Roldan Ribbed duplex (1.4362) stainless steel reinforcing bar 12mm - 32mm.

Further details are given in Techncial Approval Report TA10 5020.

Roldan SA
Santo Thomas de las Ollas
24400 Ponferrada
Leon
Spain
Tel: 00 34 987 446190
Fax: 00 34 987 446101



Cares Technical Approval Report TA1-A, B, C 5022

Cogne Acciai Speciali S.p.a. 1.4362 Duplex Stainless Steel Reinforcing Bar in accordance with Technical Approval Report TA10-5021.

Cogne Acciai Speciali S.p.a
Via Paravera 16
11100 Aosta
Italy
Tel: 00 39 0165 30251
Fax: 00 39 0165 302423



Cares Technical Approval Report TA1-A, B, C 5022

ERICO Lenton Lock mechanical couplers to reinforcing steel complying with.

CARES Quality and Operations Assessment Schedule TA1-A, TA1-B and TA1-C, which includes the performance requirements of BS5400 Part 10, fatigue class D, BS 8110 Part 1 under static loading conditions in tension and BNFL Technical Standard A.0391 for Type A mechanical splices for Seismic Category 4 structures in accordance with Technical Approval Report TA1-A, B & C -5022.

ERICO BV
Jules Verneweg 75
5015 BG, Tilburg
The Netherlands
Tel: +31 1358 35400
Fax: +31 1358 35499
Web: www.erico.com



CARES Technical Approval TA10 5023

Acciaierie Valbruna Duplex Stainless steel, 1.4362, Grade 500 reinforcing bar in the size range 20 to 40mm and decoiled bar in the size range 8 to 14mm for use in accordance with Technical Approval Report TA10-5023

Acciaierie Valbruna S.p.A.
Vialle della Scienza 25
Vicenza
36100 Vicenza
Italy
Tel: 00 39 0444 968211
Fax: 00 39 0444 963836
E-mail: roberto.bertelli@valbruna.it



Cares Technical Approval Report TA1-B 5024

Barsplice ZAP Screwlok Type 2 mechanical couplers in the size range 12 to 40 mm, using BS 4449 Grade B500B reinforcing steel, in accordance with CARES Appendix TA1-B which includes the performance requirements of BS 8110 Part 1 under static loading conditions in tension only in accordance with Technical Approval Report TA1B-5024.

Barsplice Products Inc
4900 Webster Street
Dayton Ohio Montegomery 45414
USA
Tel: (937) 275-8700 X 193
Fax: (937) 275-9525


CARES Technical Approval 5025

G.Tech Spliceman Barbreak couplers in the size range 12mm - 32mm are for themechanical connection of deformed highyield carbon steel bars for the reinforcementof concrete complying with the requirementsof BS4449 Grade B500C in accordance with TA1B-5025.

G.Tech Splicing PVT Ltd
E-49/9, 1st FloorOklhlaIndustrial Area Phase II
New Delhi 110 020
India
Tel: +91-9953004573
Fax: +91-11-26386576


CARES Technical Approval 5026

Outokumpu Stainless Ltd Duplex Stainless steel, 1.4162 (LDX 2101), Grade 500 reinforcing steel coil in the size range 12 to 25mm for use in accordance with Technical Approval Report TA11-5026.

Outokumpu Stainless Ltd. T/A ASR Rod Mill, Long Products
Sheffield
Stevenson Road
Sheffield
S. Yorkshire
S9 3XG
United Kingdom
Tel: 0114 2615217
Fax: 0114 2617153

   
CARES Technical Approval 5027

ERICO Lenton Taper Threaded Couplers standard (A12) and positional (P13 & P14) mechanical couplers to reinforcing steel in accordance with:

CARES Quality and Operations Assessment Schedule TA1-B,including the performance requirements of BS 8110: Part 1: 1997 under static loading conditions use in tension only.

Further details are given in CARES Technical Approval Report TA1-C 5027.

ERICO BV
Jules Verneweg 75
5015 BG, Tilburg
The Netherlands
Tel: +31 1358 35400
Fax: +31 1358 35499
Web: www.erico.com

   
CARES Technical Approval 5028

RFA Tech Ltd Sheartech Punching Shear Stud System for use in reinforced concrete floors designed in accordance with BS 8110 and BS EN 1992-1-1 for use with static loading comprising double headed studs in diameters from C10 to C25 for use in accordance with Technical Approval Report TA7-5028 1997 under static loading conditions use in tension only.

Further details are given in CARES Technical Approval Report TA7 5028.

RFA Tech Ltd
710 Brightside Lane
Sheffield
S9 2BR
Tel: 01543 414111
Fax: 01543 268221
Web:

   
CARES Technical Approval 5029

Erico Lenton taper thread standard (A12( N)) and positional (P13(LN) & P14(LN)) mechanical couplers to reinforcing steel in the size range 12 to 40mm, complying with CARES Quality and Operations Assessment Schedule TA1-B which includes the performance requirements of BS8110 Part 1 1997 in compression or tension under static loading conditions in accordance with Technical Approval Report TA1-C 5029

ERICO BV
Jules Verneweg 75
5015 BG, Tilburg
The Netherlands
Tel: +31 1358 35400
Fax: +31 1358 35499
Web: www.erico.com

   
CARES Technical Approval 5030

Erico Lenton taper thread standard (A12(N)) and positional (P13(LN) & P14(LN)) mechanical couplers to reinforcing steel in the size range 12 to 40mm, complying with CARES Quality and Operations Assessment Schedule TA1-C, which includes the requirements of Sellafield Ltd. Specification for Type A mechanical splices for Seismic Category 4 structures for use in tension under static loading conditions in accordance with Technical Approval Report TA1-C 5030

ERICO BV
Jules Verneweg 75
5015 BG, Tilburg
The Netherlands
Tel: +31 1358 35400
Fax: +31 1358 35499
Web: www.erico.com

   

 

Copies of the Technical Approval Reports can be downloaded in Adobe PDF format by clicking on the cover of the report below.

(Please note that files are typically 1mb and can be up to 2mb in size and may take a few minutes to download.)